TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 166 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 96 Semi- Annual Commander's Cupola Armor Shield (M113A3 and M1064A3 Only) a. Check left and right armor shield. Repair or replace cracked shield. If welds are cracked, notify supervisor (WP 0747 00). b. Check doors and clips. Straighten dents and bends. Replace cracked door or clip (WP 0747 00). c. Replace stowage strap or clamp if damaged (WP 0747 00). CLIP DOOR CLIP DOOR RIGHT ARMOR SHIELD 0155 00-146 Change 3