TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: NOTE Additional data on Chemical Agent Automatic Alarm Kit for the M113 FOV can be found in: Operator’s and Unit Maintenance Manual TM 3-6665-224-12. Repair Parts and Special Tools List TM 9-2350-277-24P. d. Check mounting screws on junction box. Tighten loose screws in junction box. Tighten loose screws to 72 lb-in (8 N m) torque. Use torque wrench (WP 0926 00, Item 79) and socket set (WP 0926 00, Item 72). e. Check grommet. Replace cracked or worn grommet. f. Check cable and circuit breaker terminal. Tighten loose connections. Replace damaged terminals. g. Check cables. Replace frayed or cracked cables (WP 0919 00). 0155 00-139 Change 3 GROMMET CABLE TERMINAL CIRCUIT BREAKER TERMINALS JUNCTION BOX CABLE