TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 158 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 94 Semi- Annual Chemical Agent Automatic Alarm Kit (M113A3 Only) a. Perform preventive maintenance checks and services every 750 miles (1,207 km), 75 hours, or semiannually, whichever comes first. b. Cable maintenance is limited to replacement of terminals (WP 0919 00). c. Remove distribution box from hull (WP 0269 00). Check terminal board and circuit breaker. Tighten loose connection. Install distribution box on hull (WP 0269 00). TERMINAL BOARD CIRCUIT BREAKER 0155 00-138 Change 3