TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 154 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 90 DELETED 91 Semi- Annual 0.4 Carrier a. Lubricate steering control lever and shaft bearings. NOTE When grease fittings will not accept GAA, notify your supervisor. 1) Every 150 hours/1500 miles or semi-annually, lubricate bearings with GAA through fitting at each end of steering support and power plant bulkhead. Use grease gun with flexible adapter. See Steering Control Bearing Lubrication Table (Table 8, page 0155 00-23). 2) Clean fittings with cleaning compound (WP 0928 00, Item 19) prior to lubrication. Check/lubricate grease fitting points after washing or fording. 0155 00-134 Change 3