TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 149 of 790

TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 88 Semi- Annual Capstan Drum and Adapter (M113A3 and M1059A3) a. Check capstan drum and adapter. Replace cracked or damaged drum or adapter. Tighten loose screws or retainer. b. If retainer can be unscrewed from drum, replace spring pin. 0155 00-129 Change 3