TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 147 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 85 Semi- Annual Tents and Stowage Brackets (M577A3 and M1068A3 Only) a. Replace tent that has tears, breaks, fraying, or other damage (WP 0627 00), (WP 0628 00), and (TM 10-5410-229-13&P). b. Tighten screws on mounting clamps and strip. 86 Semi- Annual 4.2 KW Generator Set Enclosure (M577A3 and M1068A3 Only) a. Tighten or replace loose or missing screws on enclosure to 55-60 lb-ft (75-81 N m) torque. Use torque wrench (WP 0926 00, Item 82). b. Replace damaged enclosure (WP 0674 00). 0155 00-127 Change 3