TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 136 of 790

TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: e. Test specific gravity of batteries. See TM 9-6100-200-14. f. Clean vent holes in cell caps. Replace missing or damaged caps. g. Clean terminals, posts, and bolts (WP 0340 00). h. Tighten terminals and bolts with care to avoid damage to batteries. Apply light coat of grease (WP 0928 00, Item 12) to terminals. POSTS BOLTS TERMINALS CELL CAPS 0155 00-116 Change 3