TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: BATTERIES BATTERIES BATTERY BOX WARNING Gas from batteries can explode and injure you. Do not allow sparks near batteries. Battery acid can blind or burn you. Do not get acid on your skin or eyes. d. Check electrolyte level in all cell batteries. Add distilled water as needed. See TM 9-6100-200-14. One or more batteries unserviceable, missing, cables frayed, or broken. 0155 00-115 Change 3