TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 126 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 68 Semi- Annual 1.0 Hydraulic System WARNING Hydraulic fluid is poison and can be absorbed through your skin. Wash off hydraulic fluid that contacts your skin. Fire resistant hydraulic (FRH) fluid may contain Tricresyl Phosphate which, if taken internally, can produce paralysis. Hydraulic fluid may be absorbed through the skin. Wear long sleeves, gloves, goggles, and face shield. If FRH gets in eyes, wash them immediately and get medical aid immediately. If FRH gets on skin, thoroughly wash with soap and water. Wash hands thoroughly prior to eating or smoking. a. Tighten or replace cracked or leaking fittings on hydraulic reservoir or pump (WP 0655 00, WP 0671 00, or WP 0672 00). Any hydraulic leaks, fluid not visible on sight gauge, cracked, broken, crimped, missing, or loose hardware. b. Replace leaky pump (WP 0655 00). c. Tighten tubes or hoses that leak (WP 0668 00). 0155 00-106 Change 3