TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 1) Remove driver’s power plant access panel (see your -10). 2) Place suitable container under primary fuel filter. Open drain cock and drain water and sediment from primary fuel filter. When clean fuel starts to drain out, close drain cock. 3) Repeat Step 67b2 for secondary fuel filter. 4) Check for fuel leaks at primary and secondary fuel filters while engine is running. If leak is found, remove and install primary and secondary fuel filter elements and check for proper fit and seal (WP 0202 00). 0155 00-105 Change 3 PRIMARY FUEL FILTER FUEL FILTER DRAIN SECONDARY FUEL FILTER FUEL FILTER SHELL