TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 66 Semi- Annual Fuel Cutoff a. Operate fuel cutoff to check for binding. If binding occurs, adjust (WP 0220 00). Any binding, broken, cracked, missing or loose hardware. b. Operate accelerator to check for binding linkage. If binding occurs, adjust (WP 0214 00). c. Move transmission range controller through all gears to check for binding. If binding occurs, adjust (WP 0386 00, WP 0387 00). RANGE CONTROLLER FUEL CUTOFF ACCELERATOR 0155 00-103 Change 3