TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 111 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 53 Semi- Annual Power Plant Compartments a. Open power plant front access door (see your -10) and remove hull access cover (WP 0449 00). b. Clean power plant compartment with cleaning compound (WP 0928 00, Item 19). Remove debris and wipe up spilled oil and fuel. 54 Semi- Annual Power Plant Components a. Check power plant components for looseness. Tighten any loose mounting components on the starter, generator, etc. Any damage that would prevent operation of the vehicle. MOUNTING COMPONENT MOUNTING COMPONENTS MOUNTING COMPONENTS 0155 00-91 Change 3