TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 44 Semi- Annual Final Drive a. Inspect final drive input shaft oil seals for evidence of leakage. Replace final drive seals that have leaks (WP 0404 00). Tighten screws to 21-25 lb-ft (28-34 N m) torque. Use torque wrench (WP 0926 00, Item 79). Any Class III leaks. FINAL DRIVE OIL SEAL 45 Semi- Annual Power Plant Noises a. Check power plant operation. If unusual noises are heard, repair suspect component or contact higher level of maintenance for assistance and repair. 46 Semi- Annual Exhaust System NOTE Carrier leaks exhaust when weather is cold. For this reason, carbon will be present around joints and exhaust pipe connecting clamps. This is normal. The exhaust system joints will seal after pipes heat up. Check for exhaust leaks only after engine reaches normal operating temperature of 180 to 205 F (71 to 93.3 C). 0155 00-85 Change 3