TM 9-2350-277-20-1 STE/ICE TEST 84 GENERATOR NEGATIVE CABLE VOLTAGE DROP DIAGNOSTIC TROUBLESHOOTING 0153 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Electrical connector pliers (WP 0926 00, Item 31) Jumper wire STE/ICE Test Set (WP 0926 00, Item 61) M a t e r i a l s / P a r t s Insulation tape (WP 0928 00, Item 39) P e r s o n n e l R e q u i r e d Unit Mech 63T10 R e f e r e n c e s See your -10 TM 9-4910-571-12&P E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Driver’s power plant access panel removed (WP 0441 00) Trim vane lowered (see your -10) Power plant access door open (see your -10) T 1. Remove plug W1P1 from VTM jack J1. 2. Hook up VTM to vehicle batteries TM 9-4910-571-12&P. 3. Set up Test 91 TM 9-4910-571-12&P. 4. Measure resistance between W1P1 (1), pins W (2) and P (3). 5. Does VTM read less than one ohm? YES NO GO TO BY (PAGE 0153 00-3) 0153 00-1