TM 9-2350-277-20-1 STE/ICE TEST 83 GENERATOR FIELD VOLTAGE DIAGNOSTIC TROUBLESHOOTING 0152 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Electrical connector pliers (WP 0926 00, Item 31) Jumper wire STE/ICE Test Set (WP 0926 00, Item 61) M a t e r i a l s / P a r t s Insulation tape (WP 0928 00, Item 39) P e r s o n n e l R e q u i r e d Unit Mech 63T10 Helper (H) R e f e r e n c e s See your -10 TM 9-4910-571-12&P E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Power plant access door open (see your -10) Driver’s power plant access panel removed (WP 0441 00) Trim vane lowered (see your -10) T 1. Remove plug W1P1 from VTM J1. 2. Hook up VTM to carrier batteries TM 9-4910-571-12&P. 3. Set up Test 91 TM 9-4910-571-12&P. 4. Remove harness 12354672 circuit 785 plug P6 (1) from harness 12349873 (2). 5. Measure resistance between W1P1 (3), pins M (4) and i (5). 6. Does VTM read infinity? YES NO GO TO BY (PAGE 0152 00-3) 0152 00-1