TM 9-2350-277-20-1 STE/ICE TEST 70 STARTER SOLENOID VOLTAGE DIAGNOSTIC TROUBLESHOOTING—Continued 0150 00 Y 1. Turn MASTER SWITCH OFF. 2. Set up Test 91 TM 9-4910-571-12&P. 3. Remove nut (1) and harness 12354672 circuit 775 terminal end E3 (circuit 775) (2) from solenoid positive terminal (3). 4. Ground terminal E3 to starter ground stud (4). 5. Remove plug W1P2 (5) from STE/ICE distribution box jack J2 (6). 6. Measure resistance between STE/ICE distribution box jack J2 (6), pins S (7) and M (8). 7. Does VTM read more than 0 ohms? YES NO YN 1. Faulty W1 cable. Beyond unit maintenance repair. 2. Notify supervisor. 0150 00-2