TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 537 of 858

TM 9-2350-277-20-1 NO POWER TO DC CIRCUITS (M1068A3 ONLY)—Continued 0106 00 3Y 1. Remove the following cable plugs from jacks on Power Control Enclosure: W45 plug P13 (1) from jack J33 (2) W10 plug P14 (3) from jack J34 (4) W9 plug P15 (5) from jack J35 (6) W32 plug P16 (7) from jack J36 (8) 2. Measure resistance of the following leads between terminal block E4 (9) and the following jacks on Power Control Enclosure: Lead 32G to J33 (2) socket B Lead 32H to J34 (4) socket B Lead 32J to J34 (4) socket D Lead 32L to J35 (6) socket B Lead 32N to J35 (6) socket D Lead 32P to J36 (8) socket B 3. Does multimeter read 0 ohms for all readings? YES NO 3YN 1. Faulty leads 32G, H, J, L, N, and P in Power Control Enclosure. Beyond unit maintenance repair. 2. Notify supervisor. 0106 00-5