TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 492 of 858

TM 9-2350-277-20-1 NO AC/DC INPUT TO ATCCS UPS POWER BOX (M1068A3 ONLY)—Continued 0100 00 T 1. Remove cable W43 plug P2 (1) from Roadside AC Power Extension Box A6 jack J6 (2). 2. Apply AC power to SICPS system (TM 11-7010-256-12&P). 3. Set AC LEFT OUTLETS switches on Power Control Enclosure panel to ON. 4. Measure voltage between sockets H and N of J6 (2). 5. Does multimeter read 110 volts AC or more? YES NO TN 1. Go to: No Power From Roadside AC Power Extension Box A6 (WP 0093 00). 0100 00-2