TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 468 of 858
TM 9-2350-277-20-1 NO POWER FROM CURBSIDE AC POWER EXTENSION BOX A7 (M1068A3 ONLY)—Continued 0094 00 T 1. With AC power accepted, set AC RIGHT OUTLETS switches (3) on Power Control Enclosure panel to ON, see TM 11-7010-256-12&P. 2. Measure voltage between sockets A and B of jack J31 (2). 3. Measure voltage between sockets C and D of jack J31 (2). 4. Does multimeter read 110 volts AC or more for both measurements? YES NO GO TO BY (PAGE 0094 00-4) 0094 00-2