TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 464 of 858
TM 9-2350-277-20-1 NO POWER FROM ROADSIDE AC POWER EXTENSION BOX A6 (M1068A3 ONLY)—Continued 0093 00 T 1. Remove cable W7 plug P10 (1) from Power Control Enclosure jack J30 (2). 2. With AC power accepted, set AC LEFT OUTLETS switches (3) on Power Control Enclosure panel to ON, see TM 11-7010-256-12&P. 3. Measure voltage between sockets A and B of jack J30 (2). 4. Measure voltage between sockets C and D of jack J30 (2). 5. Does multimeter read 110 volts AC or more for both measurements? YES NO GO TO BY (PAGE 0093 00-4) 0093 00-2