TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 462 of 858

TM 9-2350-277-20-1 NO DC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)—Continued 0092 00 BY 1. Turn MASTER SWITCH to OFF (see your -10). 2. Remove ten screws (1) and lockwashers (2) and lower faceplate (3). Discard lockwashers. 3. Set DC TENT INTERFACE panel circuit breaker to ON TM 11-7010-256-12&P. 4. Measure resistance between terminals (4) of circuit breaker CB16 (5). 5. Does multimeter read 0 ohms? YES NO BYN 1. Replace circuit breaker CB16 (WP 0827 00). 2. Verify no faults found. B2Y 1. Raise faceplate and secure to Power Control Enclosure with ten new lockwashers and screws. 2. Go to: Power Control Enclosure A1 DC Input/Output Inoperative (M1068A3 Only) (WP 0090 00). 0092 00-4