TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 454 of 858
TM 9-2350-277-20-1 NO AC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)—Continued 0091 00 T 1. Remove cable W32, plug P15 (1) from Power Control Enclosure jack J32 (2). 2. Apply AC power to SICPS system, TM 11-7010-256-12&P. 3. Measure voltage between socket A and socket B of jack J32 (2) and then between socket A and socket C. 4. Does multimeter read 110 volts AC or more for each measurement? YES NO GO TO BY (PAGE 0091 00-4) 0091 00-2