TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 421 of 858
TM 9-2350-277-20-1 PERSONNEL HEATER MALFUNCTIONS—Continued 0086 00 DY 1. Remove heater control box (WP 0701 00). 2. Check continuity between lead ends, from circuit breaker terminal 17 (1) and ON/OFF/START switch terminal 15 (2). 3. Does multimeter read 0 ohms? YES NO DYN 1. Repair faulty lead (WP 0382 00). 2. Verify no faults found. D2Y 1. Check continuity between lead ends from ON/OFF/START switch terminals 21 (1) and 14 (2). 2. Does multimeter read 0 ohms? YES NO D2YN 1. Repair heater switch jumper lead between terminal 21 and 14 (WP 0382 00). 2. Verify no faults found. D3Y 1. Replace heater ON/OFF/START switch (WP 0702 00). 2. Verify no faults found. 0086 00-7 Change 1