TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 410 of 858
TM 9-2350-277-20-1 RAMP WILL NOT RAISE OR FREE FALLS—Continued 0084 00 Y 1. Inspect ramp wire rope (1) and pulleys (2). 2. Are pulleys and wire rope free of damage or frayed and broken wires? YES NO YN 1. Replace wire rope and/or pulleys (WP 0657 00) or (WP 0658 00). 2Y 1. Inspect quick-disconnect fittings (1) and (2) on control valve (3), and inspect control valve (3). 2. Are fittings hooked up to control valve, and are all parts undamaged and free from leaks? YES NO 2YN 1. Repair and/or replace parts as needed (WP 0659 00) thru (WP 0668 00). 2. Verify no faults found. 0084 00-2