TM 9-2350-277-20-1 RAMP WILL NOT RAISE OR FREE FALLS 0084 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Ramp lowered (see your -10) Trim vane lowered (see your -10) Power plant access door opened (see your -10) Driver’s power plant access panel removed (WP 0441 00) Power plant rear access panels removed (WP 0439 00) Rear floor plates removed (WP 0539 00) thru (WP 0545 00) WARNING Lowering ramp could injure personnel. Make sure no one is in ramp zone before you lower ramp. If tactical situation permits, sound horn before dropping ramp. T 1. Check ramp hydraulic fluid level in sight-glass (See your -10). 2. Is fluid level correct? YES NO GO TO AY (PAGE 0084 00-3) 0084 00-1