TM-9-2350-277-20-1 Unit Maintenance Manual Volume 1 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 371 of 858

TM 9-2350-277-20-1 TRANSMISSION DOES NOT PIVOT STEER 0071 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) Multimeter (WP 0926 00, Item 30) Electrical Connector Pliers (WP 0926 00, Item 31) P e r s o n n e l R e q u i r e d Unit Mechanic Helper (H) R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Transmission in PV position Trim vane lowered (see your -10) Power plant access door open (see your -10) T 1. Remove harness 12349810 plug (1) from transmission jack (2). 2. Turn MASTER SWITCH to ON (see your -10). 3. Measure voltage between each socket on harness 12349810 plug (1) and ground. Multimeter should read 18 volts or more at sockets B (3), D (4), and E (5), and 0 volts for all remaining socket checks. 4. Does multimeter indicate an incorrect reading? YES NO TN 1. Faulty transmission. Beyond unit maintenance repair. 2. Notify supervisor. 0071 00-1