TM 9-2350-277-20-1 TRANSMISSION DOES NOT HOLD 3RD POSITION 0069 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) Multimeter (WP 0926 00, Item 30) Electrical Connector Pliers (WP 0926 00, Item 31) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Transmission in 1-3 position Trim vane lowered (see your -10) Power plant access door open (see your -10) T 1. Remove harness 12349810 plug (1) from transmission jack (2). 2. Turn MASTER SWITCH to ON. 3. Measure voltage between each socket on harness 12349810 plug (1) and ground. Multimeter should read 0 volts at socket B (3), D (4), and H (5), and at least 18 volts for all remaining socket checks. 4. Does multimeter read more than 0 volts at sockets B (3), D (4), and H (5), or less than 18 volts at all remaining sockets? YES NO TN 1. Faulty transmission. Beyond unit maintenance repair. 2. Notify supervisor. 0069 00-1