TM 9-2350-277-20-1 GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR INDICATOR—Continued 0025 00 C6Y 1. Remove harness 12349873 plug (1) from harness 12349881 jack (2) at bulkhead. 2. Measure resistance between harness 12349873 plug (1) pins B (3) and E (4). 3. Does VTM read 0 ohms? YES NO C6YN 1. Remove jumper wire and install harness 12349873 plug on generator jack. 2. Faulty harness 12349873 circuit 1/ 1A. Beyond unit maintenance repair. 3. Notify supervisor. C7Y 1. Remove jumper wire and install harness 12349873 plug on generator jack. 2. Faulty harness 12349881 circuit 1/1A. Beyond unit maintenance repair. 3. Notify supervisor. 0025 00-10