TM 9-2350-277-20-1 GENERATOR MALFUNCTIONS AS INDICATED BY BATTERY/GENERATOR INDICATOR—Continued 0025 00 B6Y 1. Replace circuit 6 lead (WP 0356 00), (WP 0357 00), or (WP 0358 00). 2. Verify no faults found. CY 1. Has regulator been adjusted? YES NO CYN 1. Adjust voltage regulator (WP 0256 00). 2. Verify no faults found. C2Y 1. Remove harness 12349873 plug (1) from generator field switch (2). 2. Start engine (see your -10). 3. Measure resistance across switch (2) pins (3) and (4) with engine idling. Use VTM. 4. Does VTM read 0 ohms? YES NO C2YN 1. Stop engine (see your -10). 2. Replace generator field switch (WP 0323 00). 3. Verify no faults found. 0025 00-6