TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 656 of 868

TM 9-2350-277-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0090 00 Table 6. Preventive Maintenance Checks and Services for Model M113A3 FOV, Semi-annually ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 90 Semi- annually 0.3 Tow Cable Every 1500 miles or semi-annually and after each use, clean and lubricate tow cable with wire brush and Grease MIL-G-18458. See Lubrication Tables (page 0090 00-7). Wipe off excess grease. 91 Semi- annually 0.3 Ramp Wire Rope Every 1500 miles or semi-annually, clean and lubricate ramp wire rope as follows: a. Lower ramp. Clean and lubricate exposed portion of wire rope with Grease MIL-G-18458. See Lubrication Tables (page 0090 00-7). b. Remove rear floor plate and raise ramp. Clean and lubricate concealed portion of wire rope with Grease MIL-G-18458. 92 Semi- annually 0.3 Machine Gun Mount Every 1500 miles or semi-annually, clean machine gun mount with cleaning compound (WP 0104 00, Item 6) and lubricate all moving parts with PL-M or PL-S as appropriate. See Lubrication Tables (page 0090 00-7). 0090 00-128 Change 3