TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 628 of 868
TM 9-2350-277-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0090 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 72 Weekly Air Cleaner WARNING Failure to decontaminate and wear protective clothing after NBC attack could result in serious health hazards to personnel. Do not service air cleaner or vent system after NBC attack until carrier has been decontaminated. If NBC exposure is suspected, all air filter medial should be handled by personnel wearing protective equipment. Consult your unit NBC officer or NBC NCO for appropriate handling or disposal instructions. Unlatched hatch covers can swing and injure personnel. Make sure hatches are latched open or closed. C A U T I O N Operating carrier with air cleaner missing or damaged can cause extensive engine damage. Do not operate carrier if air cleaner element is missing or door or gasket is missing or damaged. Check air cleaner as follows: Air cleaner element, door, or gasket is missing or damaged. a. Check latch for proper operation. Release latch at top of air cleaner housing. Swing door up and remove door. b. Check door for missing or damaged gasket. c. Check that air cleaner element is installed in air cleaner housing. 0090 00-100 Change 3