TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 626 of 868

TM 9-2350-277-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0090 00 Table 4. Preventive Maintenance Checks and Services for Model M113A3 FOV, Weekly ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 70 Weekly Power Plant Access Door and Trim Vane NOTE Do PREVENTIVE MAINTENANCE steps each week or before operation if you are operating the carrier for the first time. Carrier commander will direct and assist in weekly, monthly, and semi-annually PMCS. a. Check that access door, door seal, and trim vane are serviceable. b. Check rubber seal for breaks, brittleness, cracks, and poor seating. c. Check access door for watertight fit. Make sure door locks. Access door will not close and lock. d. Check trim vane for cracks, warps, and separation of plywood. Operate trim vane control handle. Make sure adjustment is right in both the stowed and open position. 0090 00-98 Change 3