TM 9-2350-277-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0090 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: b. Check ramp hydraulic fluid level with ramp down and carrier on level ground. Fluid level must be visible halfway up in hydraulic tank sight glass. To add FRH, remove fill plug and preformed packing from top of tank. Add FRH as needed. See Lubrication Tables (page 0090 00-7). Install fill plug and new preformed packing. Fluid is not visible half way up in sight glass. Breather cap is missing. HYDRAULIC SYSTEM TANK FILL HYDRAULIC SYSTEM TANK FLUID LEVEL CHECK 0090 00-66 Change 3