TM 9-2350-277-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0090 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 30 During Mortar Carrier Tube Assembly GUNNER M1064A3 ONLY See TM 9-1015-250-10 to conduct PMCS for 4.7 inch, 120-mm mortar. Fault listed in “Equipment Not Ready/ Available If:” column of mortar TM. 31 During Generator Set CREWMEMBER M577A3 AND M1068A3 See TM 5-6115-596-14 for PMCS procedures. Fault listed in “Equipment Not Ready/ Available If:” column of generator TM. 32 During Auxiliary Power Unit (APU) CREWMEMBER M577A3 AND M1068A3 See TM 9-6115-664-13&P for PMCS procedures. Fault listed in “Equipment Not Ready/ Available If:” column of APU TM. 0090 00-55 Change 3 Personnel sitting in open not expose more than head and shoulders to name tag 32.1 Ensure all personnel are buckled in their seats. During Seatbelts COMMANDER Personnel sitting in open hatch area must not expose more than head and shoulders to name tag level, except when firing weapons. level except when firing a weapon. hatch area must