TM 9-2350-277-10 TROUBLESHOOTING TABLES—Continued 0089 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Operator NBC KIT Table 9. Troubleshooting Procedures. MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. INSUFFICIENT AIR FLOW AT ALL STATIONS. 1. Check to see if spring clip is down over air intake openings on air purifier. Raise spring clip from air intake openings on air purifier (WP 0081 00). 2. Check to see if air hoses are kinked or pinched. Straighten or replace air hoses (WP 0081 00). 3. Check to see if it there are any loose air hose connections. Tighten loose hose connections (WP 0081 00). 2. AIR FLOW TOO HIGH AT ALL STATIONS. 1. Check to see if air purifier is out of adjustment. If air purifier is out of adjustment, notify unit maintenance. 3. GAS PARTICULATE FILTER WILL NOT OPERATE WHEN SWITCH IS IN ON POSITION. 1. Check to see if AIR PURIFIER SWITCH is in OFF. Turn AIR PURIFIER SWITCH ON. 2. Check to see if ground wire is loose or missing. Notify unit maintenance of loose or missing ground wire. 3. Check to see if electrical cable assemblies are loose or missing. Notify unit maintenance. 0089 00-21/22 blank Change 3