TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 519 of 868
TM 9-2350-277-10 TROUBLESHOOTING TABLES—Continued 0089 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Operator BILGE PUMPS Table 6. Troubleshooting Procedures. MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. BILGE PUMP DOES NOT WORK WITH THE BILGE PUMPS SWITCH ON. 1. Check to see if MASTER SWITCH is OFF. Turn MASTER SWITCH ON. 2. Check to see if bilge pump strainers or outlets are clogged. Clean bilge pump strainers or outlets (WP 0096 00). 3. Check to see if bilge pump vents are blocked. Clean bilge pump vents (WP 0096 00). If you cannot get to the bilge pump to clean it because of a load in the personnel compartment, cycle the BILGE PUMPS switch ON and OFF (WP 0004 00) a few times. That will usually start the pump. 0089 00-15/16 blank Change 3