TM 9-2350-277-10 OPERATE GLOW PLUG COLD START SYSTEM (MANUAL OVERRIDE) — Continued 0086 00 NOTE If engine does not start, wait 10 seconds and repeat above procedure. If engine fails to start after four attempts, stop manual override procedure and notify unit maintenance. 5. After engine starts, release START switch. Continue to hold GLOW PLUG switch while slowly pressing throttle. 6. Release GLOW PLUG switch when engine is running. Raise engine speed until engine reaches 1200 RPM. Do not exceed 1800 RPM (maximum). 7. Reduce engine speed to 1000-1200 RPM. Hold until engine reaches normal operating temperature (190 -230 F). END OF TASK 0086 00-2