TM 9-2350-277-10 OPERATE NBC KIT — Continued 0080 00 TURN NBC KIT ON IN CARRIER WITHOUT LITTER KIT WARNING Filters and masks of the NBC system will not protect you against carbon monoxide, ammonia, acid, or solvent fumes. Be sure the carrier is properly ventilated. Do not let any filters of the NBC system get wet. Water will destroy their ability to take the deadly chemical and biological agents out of the air. Contaminated filters must be handled using adequate precautions (FM 21-40) and must be disposed of by trained personnel. If it is very cold outside, there is danger of frostbitten lungs from inhaling the cold air. Do not connect the hoses to your M42 mask canister until NBC system has been operating at least 15 minutes with the heater turned on. NOTE For operation of M42 protective mask, refer to TM 3-4240-346-10. 1. All crew members must put on their M42 protective mask. Adjust the mask. 2. Remove spring clip from air intake openings on air purifier. 3. Deleted 0080 00-4 Change 2