TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 467 of 868

TM 9-2350-277-10 OPERATE NBC KIT — Continued 0080 00 5. If only three outlets are used, cover the fourth with a solid cap. When less than three are used, cover one of the unused outlets with a solid cap and the other with a cap with a hole. NOTE Attach a hospital hood, with its bottom folded, to any open hose to prevent too much air loss. TURN NBC KIT OFF IN AMBULANCE WITH LITTER KIT 1. Help the patients to remove their hospital hoods. Uncouple the hoses from the inlet adapters on the hoods. 2. Turn the air purifier switches OFF. 3. Stow hoses connected to Y connectors out of the way. 4. Install spring clip over air intake openings on the air purifier. 5. Clean air purifier housing with a clean cloth as soon as possible after operation. 0080 00-3 Change 2