TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 465 of 868
TM 9-2350-277-10 OPERATE NBC KIT 0080 00 THIS WORK PACKAGE COVERS: Turn NBC Kit On In Ambulance With Litter Kit (page 0080 00-1). Turn NBC Kit Off In Ambulance With Litter Kit (page 0080 00-3). Turn NBC Kit On In Carrier Without Litter Kit (page 0080 00-4). Turn NBC Kit Off In Carrier Without Litter Kit (page 0080 00-7). INITIAL SETUP: M a i n t e n a n c e L e v e l Operator P e r s o n n e l R e q u i r e d Soldier R e f e r e n c e s TM 3-4240-280-10 E q u i p m e n t C o n d i t i o n NBC Kit installed TURN NBC KIT ON IN AMBULANCE WITH LITTER KIT WARNING Filters and masks of the NBC system will not protect you against carbon monoxide, ammonia, acid, or solvent fumes. Be sure the carrier is properly ventilated. Do not let any filters of the NBC system get wet. Water will destroy their ability to take the deadly chemical and biological agents out of the air. Contaminated filters must be handled using adequate precautions (FM 21-40) and must be disposed of by trained personnel. If it is very cold outside, there is danger of frostbitten lungs from inhaling the cold air. Do not connect the hoses to your M42 mask canister until NBC system has been operating at least 15 minutes with the heater turned on. 1. Remove spring clip from air intake openings on air purifier. 0080 00-1 Change 2