TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 381 of 868

TM 9-2350-277-10 REMOVE/INSTALL 4.2 KW GENERATOR SET (M577A3 AND M1068A3 ONLY) 0054 00 THIS WORK PACKAGE COVERS: Removal (page 0054 00-1). Installation (page 0054 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Operator P e r s o n n e l R e q u i r e d Driver Crew E q u i p m e n t C o n d i t i o n Carrier stopped REMOVE 1. Remove waterproof cover if auxiliary unit is to be removed from enclosure. 2. Loosen thumbscrews and clamps securing generator set to enclosure. Turn clamps 90 degrees. 0054 00-1