TM 9-2350-277-10 OPERATE FIXED FIRE EXTINGUISHER SYSTEM 0031 00 THIS WORK PACKAGE COVERS: Operate Fixed Fire Extinguisher (Outside) (page 0031 00-2). Operate Fixed Fire Extinguisher (Inside) (page 0031 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Operator P e r s o n n e l R e q u i r e d Driver or soldier R e f e r e n c e s TM 3-1040-285-10 E q u i p m e n t C o n d i t i o n Fire extinguisher installed and seal unbroken WARNING If CO2 is discharged into engine compartment while engine is running, engine exhaust may be poisonous. Poisonous gas can injure you. Stop engine before you discharge CO2. If CO2 is discharged while engine is running, do not breathe engine exhaust. WARNING Engine fan can blow away CO2 before fire is extinguished. Personnel can get burned. Equipment can get damaged. Stop engine before you operate fire extinguisher. NOTE Notify unit maintenance after fixed fire extinguisher is discharged. 0031 00-1