TM 9-2350-277-10 OPERATE PERSONNEL HEATER — Continued 0028 00 NOTE Heater startup varies with the type of heater installed in your carrier. For heater P/N 10560M24B1, see Step 5 and Step 6. For heater P/N MF510B or P/N MF510C, see Step 7 and Step 8. For heater P/N 5000-30178, see Step 9 and Step 10 and also TM 9-2540-207-14&P. 5. Move RUN-OFF-START switch to START for 2 minutes. If HEATER light does not come on, move RUN-OFF-START switch toOFF for 10 seconds. Move RUN-OFF-START switchto START for 1 minute. If HEATER light does not come on, move RUN-OFF-START switch toOFF for 10seconds. Move RUN-OFF-START switch to START for 1 minute. If heater fails to start after third try, troubleshoot heater, see WP 0087 00. 6. Move RUN-OFF-START switch to RUN as soon as HEATER light comes on. Do not stop in OFF position. NOTE Step 7 and Step 8 apply to heater P/N MF510B or P/N MF510C only. 7. Move RUN-OFF-START switch to START for 4 minutes. If HEATER light does not come on, move RUN-OFF-START switch toOFF. Wait at least 15 minutes. Move RUN-OFF-START switch to START for 4 minutes. If heater failsto start after second try, troubleshoot heater, see WP 0087 00. 8. Move RUN-OFF-START switch to RUN as soon as HEATER light comes on. Do not stop in OFF position. 0028 00-3 Change 3