TM-9-2350-277-10 Operator Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 240 of 868

TM 9-2350-277-10 START ENGINE WITH OUTSIDE POWER SOURCE — Continued 0022 00 WARNING Electrical slave cable can be improperly connected causing electrical spark or fire. Personnel can be killed or injured. Equipment can be damaged. Match connector guide lug and cable prongs with receptacle hole. 4. Connect slave cable to auxiliary power receptacle on disabled carrier. 5. Connect slave cable to auxiliary power receptacle on source carrier. 6. Start engine of source carrier. See task: START ENGINE, (WP 0021 00). 7. Run engine on source carrier at a fastidle (1000 rpm) for 5-10 minutes to show charging on BATT GEN indicator. NOTE In cold weather areas, air box heater can be switched on to heat engine on disabled carrier before attempting to start it. 8. Start engine on disabled carrier. See task: START ENGINE, (WP 0021 00). 0022 00-4 Change 1