TM 9-2350-277-10 START ENGINE — Continued 0021 00 32. Set hand throttle control for 800 to 1000 rpm, and run engine for at least 10 minutes to warm up transmission. 33. Run engine at 1000 to 1200 rpm for about 5 minutes or until ENGINE COOLANT TEMPERATURE GAGE indicates 185 F. 34. Reduce engine to idle speed (650-700 rpm). To drive carrier, see task: DRIVE CARRIER (WP 0023 00). LEVEL TRANS FILTER TRANS OIL PARKING HEADLIGHTS CLOGGED LOW PRESS BRAKE HI BEAM MASTER SWITCH ON TEMP F RIGHT FUEL TANK LEFT START IR-BO SELECT OFF ON I.R. B.O. BATT GEN INDICATOR RPM HUNDREDS 160 200 120 240 10 20 30 40 50 60 E F 1/4 1/2 3/4 20 25 30 15 10 5 O 40 35 BILGE PUMPS OFF ON MARKER LIGHT UNLOCK BO STOP SER PANEL BRIGHT DIM DRIVE PARK 0 0 0 0 0 0 M I L E S PE R H O U R B A T T G EN ER A T O R TH DRI HOUR 10 OFF ON BILGE PUMPS ON DRIVERS FAN WAIT GLOW PLUG D.N.V. POWER END OF TASK 0021 00-17/18 blank Change 2