TM-9-2350-275-BD Battlefield Damage Assessment and Repair for M113 Family Download

Page 147 of 224

TM 9-2350-275-BD COMMUNICATIONS SYSTEM 11-29. COAXIAL CABLE REPAIR General Information This procedure gives instructions and identifies materials coaxial or other shielded cables when standard replacement Limitations: None Personnel/Time Required 1 soldier 20 minutes Materials/Tools: See illustrations in this procedure for materials required. Other Option: See shielded cable repair procedures in electrical chapter Procedural Steps: NOTE recommended for repair of parts are not available. of TM 9-2350-276-BD. Do not attempt to repair broken or damaged coaxial cables unless absolutely necessary. Replace the entire cable whenever possible. 1. If replacement is not practical, install a matching plug and jack of the proper size and type for splicing the damaged or broken part. 11-41