TM-9-2350-261-PMC Preventative Maintenance Checks PMCS for M113A2 M577A2 M106A2 M125A2 M1059 Download

Page 7 of 12

*30. Check heaters (only if needed in operation). a. Personnel heater electrical circuits b. Coolant heater c. Coolant heater electrical circuits d. Electronic equipment heater (M577A2) WARNING Engine must be stopped to do steering/braking PMCS Do not press steering lock buttons when vehicle is moving. Steering levers must engage in 2nd or 3rd *31. *32. 33. 34. notch of quadrant. CAUTION Stop carrier before shifting into reverse. Check steering, braking, shifting, and throttle controls DURING OPERATION CHECKS GUNNER (M106A2, M125A2) Conduct daily PMCS for 4.2 inch (107-MM) mortar using TM 9-1015-215-10 or, for 81-MM mortar, using TM 9-1015-200-10. NOTE Assist carrier commander and driver in performing PMCS on vehicle. AFTER OPERATION CHECKS CARRIER COMMANDER Check fuel tank filler cap. Service smoke grenade launcher (M113A2, M1059). NOTE Assist driver on suspension PMCS 7 of 8