TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 86 of 788
TM 9-2350-261-34 VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068 ONLY) — Continued 0011 00 4Y 1 . A pply external sou rce of A C pow er to SICPS carrier. See TM 11-7010-256-12&P. 2. Measure voltage between XK2 relay socket terminal 1 (1) and terminal block E4 post 1 (2). Repeat check for terminals 3 (3) and 7 (4) of XK2 relay socket. 3. Does multimeter read 110 volts AC for each measurement? 4YN 1. Replace XK2 relay (WP 0084 00). 2. Verify no faults found. 0011 00-6