TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 764 of 788
TM 9-2350-261-34 FABRICATED TOOLS — Continued 0106 00 Special Purpose Power Cable for Power Control Enclosure (M1068 Only) MATERIALS/PARTS REQUIRED W3 Cable P/N 12383899 Plug WC596-13-3 or WC596/100-1 NOTES 1. Remove connector labeled W3 P1 (A3 J1) from W3 cable. 2. Cut cable to required length (for connecting power control enclosure to AC outlet). WARNING Incorrect polarity can harm personnel and damage equipment when power is applied to the power control enclosure. Make sure polarity is correct when installing plug on cable. 3. Install new plug WC596-13-3 or WC596/100-1 on W3 cable. Connect per wiring diagram. 4. Purpose of cable is to connect the power control enclosure to shop AC power. 0106 00-2