TM-9-2350-261-34 Direct and General Maintenance Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 731 of 788
TM 9-2350-261-34 INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT (M113A2 ONLY) — Continued 0098 00 31. Install battery box cover (see your -20). 32. Install front personnel seat back rest (3) to sponson brackets with two screws (2) and new locknuts (1). 33. Test electrical continuity of chemical alarm kit circuits (see your -20). FOLLOW-THROUGH STEPS 1. Raise and lock ramp (see your -10). 2. Stop engine (see your -10). END OF TASK 0098 00-9/10 blank